Authority: | Gujarat Maritime Board |
Client: | Sanjay Construction Co, Ahmedabad. |
Scope of Work: | Design of Movable Gantry for Piling, Construction methodology. |
Authority: | Relience Industries Limited, Hazira | |
Client: | Sanjay Construction Co, Ahmedabad. | |
Technical Data : | ||
Pile |
1.25 m dia, 9 Nos with 1.5m Th. Pile Cap | |
Pull |
113 T | |
Wave |
4 m/sec | |
Water Current |
2.0m Ht | |
Scope of Work: |
Design of Platform for Piling over dummy steel Pile.
Design of MD3 & MD4 and approval from RIL’s consultant. |
Authority: | Paradip Port Trust, Orissa |
Client: | J. M. Baxi & Co. |
Technical Data : | |
Plateform Size |
50 m x 15m for 5500 DWT vessel |
Pile |
1.0 m dia, 39 Nos, |
Pull |
60 T ( 30 T at each end) |
Scope of Work: |
Checking & Certifying the Structural Design.
Third Party Inspection of Execution Work. |
Authority: | Gujarat Maritime Board. |
Client: | Hung Hua Construction Co. Ltd. & Ranjit Buildcon Co. Ltd. (J.V.) |
Technical Data : | |
Jetty Size : |
200 m x 16.255m for 50000 DWT vessel |
Pile : |
1.0 m dia, 176 Nos, |
Block Quay Wall : | 200 m |
Scope of Work: | Structural Design of Jetty.
Approval of Design form GMB’s TPI Consultant. |
Authority: | Kandala Port Trust. |
Client: | IFFCO - Kandala, WAPCOS Ltd.- Gandhinagar |
Technical Data : | |
Jetty Size : |
120 m x 20 m |
Pile : |
1.2 m dia, 75 Nos, |
Scope of Work: | Approve the Structural Design done by IIT Chennai.
Periodical Site Supervision. |
Owner : | Ultratech Cement Limited. |
Client/Contractor: | Sanjay Construction Co. |
Technical Data : | |
Jetty Size : |
210 m x 32 m for 60000 DWT Vessel. |
Pile : |
1.2 m dia, 110 Nos, 750 dia 13 No Fender Pile |
Scope of Work: | Planning of Construction Methodology.
Suttering Design for Different Precast Unit. Gantry Design for Piling work. Launcher Design for Precast Beam to place at proper place. Design of Bollard with foundation for 90 T Pull. To get approval of all the above work from UCL’s Consultant. |
Client: | Ultratech Cement Limited |
Scope of Work: | Structural Design for Fender Faccia Beam as Precast and Supporting system. |
Technical Data : | 15m x 140m Approach , 15m x 150m Jetty
Shore Protection Work for 300m |
Scope of Work: | Design of Jetty.
Shore Protection work. |